r2186-r2216
Différences entre les releases 2186 et 2216 de LMDZ
------------------------------------------------------------------------ r2216 | oboucher | 2015-02-23 17:21:48 +0100 (Mon, 23 Feb 2015) | 3 lines Olivier Boucher: updating sea-salt aerosol optical properties with hygroscopicity data consistent with INCA emission routine ------------------------------------------------------------------------ r2215 | oboucher | 2015-02-23 17:21:29 +0100 (Mon, 23 Feb 2015) | 3 lines Olivier Boucher: updating sea-salt aerosol optical properties with hygroscopicity data consistent with INCA emission routine ------------------------------------------------------------------------ r2214 | oboucher | 2015-02-23 17:15:56 +0100 (Mon, 23 Feb 2015) | 2 lines Olivier Boucher: adding routine for initializing aerosol LW optical properties ------------------------------------------------------------------------ r2213 | oboucher | 2015-02-23 16:27:59 +0100 (Mon, 23 Feb 2015) | 2 lines Olivier: Adding call to aeropt_lw_rrtm to initialize LW aerosol properties ------------------------------------------------------------------------ r2210 | fhourdin | 2015-02-17 18:49:30 +0100 (Tue, 17 Feb 2015) | 8 lines Control of convective scavenging by .def files Conrôle du lessivage convectif dans les fichiers .def ccntrAA= 1. # fraction d'aerosol en phase condensee dans l'ascendance adiab ccntrENV=1. # fraction d'aerosol en phase condensee dans les melange (Emanuel) coefcoli=1.e-3 # efficacité de collision ------------------------------------------------------------------------ r2209 | emillour | 2015-02-16 08:34:28 +0100 (Mon, 16 Feb 2015) | 6 lines Update of the slab ocean by Francis Codron. There are now 3 possibilities for the "version_ocean" slab type: sicOBS = prescribed ice fraction. Water temperature nearby is set to -1.8°C and cannot become lower. sicNO = ignore sea ice. One can prescribe a fraction, but the nearby ocean evolves freely, depending on surface fluxes: temperature can go below freezing point or above... sicINT = interactive sea ice. EM ------------------------------------------------------------------------ r2208 | fhourdin | 2015-02-13 13:42:13 +0100 (Fri, 13 Feb 2015) | 3 lines Suppression d'un print. ------------------------------------------------------------------------ r2207 | fhourdin | 2015-02-13 09:40:30 +0100 (Fri, 13 Feb 2015) | 3 lines Bi-gauussienne, suite. ------------------------------------------------------------------------ r2206 | fhourdin | 2015-02-13 08:23:14 +0100 (Fri, 13 Feb 2015) | 3 lines Nouvelle routine pour le schéma bi gaussien ------------------------------------------------------------------------ r2205 | fhourdin | 2015-02-13 08:22:32 +0100 (Fri, 13 Feb 2015) | 13 lines Introduction of a bi-gausian descrption of the subgrid scale distribution of water associated with deep convection. Introduction d'un schéma bi-gausien pour la distribution sous maille de l'eau associée à la convection profonde. Contrôlé par iflag_cld_cv=2 (1 pour le schéma de Bony et Emanuel 2001) autres paramètres de contrôle : tau_cld_cv et coefw_cld_cv Arnaud Jam ------------------------------------------------------------------------ r2204 | fhourdin | 2015-02-13 00:41:23 +0100 (Fri, 13 Feb 2015) | 4 lines Correction pour le 1D : Ne marchait plus en 1D depuis le test sur iim multiple de 8. ------------------------------------------------------------------------ r2202 | lguez | 2015-02-10 16:21:39 +0100 (Tue, 10 Feb 2015) | 1 line Added tests in the compilation scripts: iim should be a multiple of 8 and dyn3dpar should not be used. ------------------------------------------------------------------------ r2201 | crio | 2015-02-10 15:23:19 +0100 (Tue, 10 Feb 2015) | 11 lines Expérience du tube de dentifrice: Ajout d'un terme de grande-échelle dans la fermeture du schéma de convection. La fraction de la convergence grande-échelle de masse au LFC ajoutée au flux de masse à la base calculé par la fermeture en ALP est controlée par coef_clos_ls lu dans physiq.def (valeur comprise entre 0 et 1, 0 par défaut). Tube of toothpaste experiment: Additional large-scale term in the closure formulation of the deep convection scheme. The fraction of the large-scale convergence of mass at LFC additioned to the cloud-base mass-flux given by the ALP closure is controlled by coef_clos_ls read in physiq.def (value between 0 and 1, 0 by default). ------------------------------------------------------------------------ r2200 | acozic | 2015-02-09 10:53:34 +0100 (Mon, 09 Feb 2015) | 2 lines Aco : add some variable in inca routine call to correct a bug on time_axis with xios output ------------------------------------------------------------------------ r2199 | emillour | 2015-02-09 09:59:05 +0100 (Mon, 09 Feb 2015) | 3 lines Follow-up of r2197; some compilers (e.g. ifort) impose that parameter types be declared before or at the same time as the associated values. EM ------------------------------------------------------------------------ r2198 | emillour | 2015-02-09 09:36:55 +0100 (Mon, 09 Feb 2015) | 3 lines Bug fix for aquaplanets: definition of limit.nc file variable types (real/double) must match used nf_put_..._double/real netcdf functions. EM ------------------------------------------------------------------------ r2197 | emillour | 2015-02-09 08:13:05 +0100 (Mon, 09 Feb 2015) | 3 lines Added 'implicit none' statements and proper variable definitions where they were missing. EM ------------------------------------------------------------------------ r2195 | jyg | 2015-02-06 11:50:14 +0100 (Fri, 06 Feb 2015) | 1 line Inclusion of IMPLICIT NONE and some cleaning in cv3_inip.F90 ------------------------------------------------------------------------ r2194 | fhourdin | 2015-02-05 12:29:37 +0100 (Thu, 05 Feb 2015) | 8 lines Use of add_phys_tend to add the tendencies from radiation. In order to control temperature range after radiation. Utilisation de add_phys_tend pour ajouter les tendances du rayonnement, de façon à contrôler les températures après cet ajout. ------------------------------------------------------------------------ r2193 | fhourdin | 2015-02-04 07:48:02 +0100 (Wed, 04 Feb 2015) | 8 lines New option iflag_trig_bl for triggering : 1 : ALE computed from the PDF of thermals 2 : mean ALE with moist cape 3 : mean ALE with dry cape Catherine et Frédéric ------------------------------------------------------------------------ r2192 | musat | 2015-02-03 11:22:28 +0100 (Tue, 03 Feb 2015) | 8 lines Suppression print superflus --- Deleting some superfluous prints ------------------------------------------------------------------------ r2191 | fhourdin | 2015-02-03 11:00:57 +0100 (Tue, 03 Feb 2015) | 4 lines Ajout du cas 1D CINDY-DYNAMO, utilisant le nouveau format standard, amené à être étendu aux autres cas. Addition of the CINDY-DYNAMO 1D case, using the new standard format for 1D cases, that will be extended to all 1D cases. Catherine Rio ------------------------------------------------------------------------ r2190 | fhourdin | 2015-02-02 17:59:13 +0100 (Mon, 02 Feb 2015) | 3 lines Correction lecture flux descendant LW ------------------------------------------------------------------------ r2189 | fairhead | 2015-01-31 10:31:49 +0100 (Sat, 31 Jan 2015) | 7 lines Suppression print superflus ------------------- Deleting some superfluous prints ------------------------------------------------------------------------ r2188 | fhourdin | 2015-01-30 17:25:12 +0100 (Fri, 30 Jan 2015) | 44 lines Modification of the numerical scheme for coupling of surface temperature with Orchidee. Modification du schéma numérique pour le couplage de la température de surface avec Orchidee. Cette modification concerne la gestion des pas de temps différents pour l'appel au rayonnement et au modèle de surface. Orchidee prend en entrée le flux LW descendant. Dans la version actuelle, on recalculait ce flux descendant à partir du flux net issu du rayonnement, comme si il ne variait pas dans le temps. pbl_surface recalculait ensuite un flux descendant en ajoutant au flux net descendant l'emission du sol, simga Ts**4. Mais du coup, si la température du sol partait en dérive froide entre deux appels au rayonnement, on ne tenait pas compte du rappel exercé par le rayonnement : le flux descendant ne bouge pas et réhauffe la surface tandis que celle ci se refroidit de moins en moins par émission LW. Dans la nouvelle version, on passe le LWdown directement depuis le rayonnement. Il s'agit de deux hypothèses extrêmes : Avant on supposait que le LWnet ne bougeait pas d'un appel au rayonnement sur l'autre. Maintenant on suppose que c'est le LWdown. La réalité est entre les deux car le WLdown a tendance à suivre la température de surface, quand la température de l'air et de la surface sont fortement couplées. La nouvelle façon de faire devrait limiter la dérive vers le froid dans les conditions de découplage nocturne. Un découplage extrême avait amené à limiter la fonction de Richardson dans le calcul du coefficient de trraînée Cd f(Ri) à F(ri) > 0.6 plutôt que 0.1 sur le cas 1D Dice. Les corrections pourraient également résoudre des plantages aléatoires sur l'Himalaya. Jean-Louis Dufresne, Fuxing Wang, Frédéric Hourdin PS : les changements concernent l'interface entre physiq et pbl_surface, ainsi que phyredem et phyetat0 pour garantir 1+1=2. On en a profité pour faire un brin de toilette. ------------------------------------------------------------------------ r2186 | fairhead | 2015-01-29 15:40:29 +0100 (Thu, 29 Jan 2015) | 3 lines Need to have a rethink ------------------------------------------------------------------------